Loop Detector

Print
Used wherever vehicles have to be detected, for example: monitoring and safe guarding access ways or counting vehicles.
Sales price without tax $1.00
Description

Loop Detector are used wherever vehicles have to be detected, for example: monitoring and safe guarding access ways or counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems in car parks or activating card dispensers in car parks.

 

Technical Specs

-Self-tuning range : 80-500µH

-Sensitivity : 4-step selectable per channel:

-High: 0.02% L/L

-Medium High: 0.05% L/L

-Medium Low: 0.1% L/L

-Low: 0.5% L/L

     -Frequency:4-step adjustable, 20-70kHz (frequency determined by loop geometry)

     -Output configuration:1 output relays per channel (fail-safe) Fail secure (factory option) 

     -Automatic Sensitivity Boost:Switch selectable

     -Pulse output duration:Approx. 150ms (factory option 250ms) Presence time : Selectable, limited or permanent Limited : Presence 1 hour for 3% L/L

     -Protection: Loop isolation transformer, zener diode clamping on loop inputs and gas discharge tube protection

-Power requirements: 230V AC +/- 15% 48-60Hz (PD232) Requirement : 1.5VA max @ 230V

-Output relays: 6A  230V AC; N/O contact per channel (fail-safe) Operating temp range : -40°C to +80°C (circuit sealed against condensation) Material : High heat ABS blend

-Dimensions (mm): 76 x 40 x 78   Mounting : Shelf or DIN rail socket

-Connector: Single rear-mount 11-pin submagnal (86CP11) Option : 1 meter flying lead

 

 

Self-tuning range           : 80-500µH

Sensitivity                        : 4-step selectable per channel:

High                              : 0.02%    L/L

Medium High                : 0.05%    L/L

Medium Low                 : 0.1%    L/L

Low                               : 0.5%    L/L

Frequency                     : 4-step adjustable, 20-70kHz (frequency determined by loop geometry) Output configuration      : 1 output relays per channel (fail-safe) Fail secure (factory option) Automatic Sensitivity Boost: Switch selectable

Pulse output duration     : Approx. 150ms (factory option 250ms) Presence time                : Selectable, limited or permanent Limited     : Presence 1 hour for 3%  L/L

Protection                     : Loop isolation transformer, zener diode clamping on loop inputs and gas discharge tube protection

Power requirements       : 230V AC +/- 15% 48-60Hz (PD232) Requirement                  : 1.5VA max @ 230V

Output relays                 : 6A  230V AC; N/O contact per channel (fail-safe) Operating temp range : -40°C to +80°C (circuit sealed against condensation) Material     : High heat ABS blend

Dimensions (mm)           : 76 x 40 x 78   Mounting        : Shelf or DIN rail socket

Connector                     : Single rear-mount 11-pin submagnal (86CP11) Option                                    : 1 meter flying lead